UL62368-1

UL62368-1 is a safety regulation standard based on the HBSE danger protection engineering principle. Th is   concept is slightly different from the current regulation standard, which covers the danger to people and the environment in information products and audio and video equipment, as well as the corresponding danger protection. In fact, UL62368-1 is a combined version of AV audio UL60065 and IT information UL60950.

Head-mountes VR glasses

  Head-mounted VR g lasses display device mainly close people's vision and hearing to the outside world, Guid ing   user s   to create a sense of being in a virtual environment. G enerally such products to be exported to the United States must be transacted   the FCC test report.

Environmental reliability tests

  Generally, environmental reliability tests are divided into three categories: mechanical environment test, climate environment test and comprehensive environment test. Mechanical environment test mainly includes mechanical vibration, mechanical impact, drop, collision, steady-state acceleration test, climate environment test mainly includes the test of temperature, temperature and humidity test, pressure test, water test, test, salt spray test, sand dust test, gas corrosion test, including comprehensive environment pressure comprehensive test, temperature vibration, temperature and humidity vibration comprehensive test, temperature pressure humidity comprehensive test, etc.

Hot and humid test

  Hot and humid environment generally exists in the whole life cycle of the transportation, storage and use of electronic products. Under the influence of hot and humid environment, the insulation materials and metal surfaces in electronic products will adsorb water vapor, leading to the degradation of products. At the same time, under the joint action of humidity, temperature and electrical stress, it will cause electrochemical reaction and metal corrosion, resulting in the insulation resistance of electronic equipment, leakage increase, serious flying arc, breakdown circuit damage and other phenomena. What is the   hot and humid   test Hot and humid   test can be divided into constant hot and humid   test , alternating hot and humid   test, is the environmental stress of temperature stress and humidity stress two environmental stress, need to use constant hot and humid   test chamber   or alternating hot and humid   test chamber ,   effect of typical environment is mainly caused by t

Procedures and methods of plug and pull force testing

  Test procedures and methods 1. Preparation: Select the appropriate plug and pull force test equipment and fixtures, and adjust the equipment parameters according to the test requirements. Conduct visual inspection of the connector to ensure it is free from damage or contamination. 2. Install the connector: according to the product specification or standard requirements, correctly install the connector to the test equipment, to ensure the accurate alignment between the plug and the socket. 3. Set the test parameters: according to the test requirements, set the size, frequency and number of insertion and pulling force parameters. 4. Test: start the test, insert and pull the operation according to the set parameters, and record the insertion and pull force value of each times. 5. Data analysis: According to the test results, conduct data analysis and processing, calculate the average insertion and pulling force value, the maximum insertion and pulling force value, the change trend of th

Plug and Pull Force Testing

 What is Plug and Pull Force Testing The test method of plug and pull force is an experimental method to test the performance of the connector . This method mainly by simulating the actual use situation, p lug and pull the connector multiple times, in order to evaluate the reliability and durability of the plug and pull   performance. Test principle and purpose Its   test method is to insert and pull the connector by applying a certain force and frequency, and observe the change of the plug and pull force under different times. Through this test evaluates the performance of the connector to determine its reliability and durability in practical use. The plug   and pull test method is a common, which is widely used in electronics, communication, aerospace and other fields. Through th e   method, we can effectively evaluate the plug and pull   performance of the connector, provide the basis for product design and selection, and ensure the good reliability and durability of the product in

What is RCM mark?

  RCM logo is led by the Queensland government and Victoria government .  The purpose is to verify the combination of safety regulations and EMC .   A s you know, Australia's safety (SAA) and C-TICK is separate certification, SAA application can be different national factories and traders, t he filing subject of C-TICKR is the legally registered company in Australia. In the application process of RCM, the legal entity of Australia is required, that is, RCM is a certification mode that needs to be guaranteed by an Australian company. For most products ,  need to obtain SAA certificate and EMC test report, can register as RCM certificate, not instead of SAA certification, just added requirements to EMC on the basis of SAA certification, for the non-mandatory electrical product safety, can not apply for electrical safety certificate, but directly use electrical safety test report + C-TICK test report (EMC report), if it is mandatory product, must first obtain electrical safety certifi

SAA certification

  SAA certification can be said to be mandatory certification in Australia, which is in Australia and New Zealand. Australia and New Zealand are two less populated countries, with a population of 23 million, but the consumption power is very high . The widely recognized SAA (Standards Association of Australia) is actually a standard research institute, responsible for the formulation and revision of standards. The electronic and electrical products which e nter Australia (including Australia and New Zealand) must pass the certification, put on the certification certificate number on the product, to legally enter the sales in Australia. Licensing agency: Currently, the SAA issuers are SAI, DOIR (Q number), and DOFT (N number). In general, the application cycle for Australian SAA certification for common IT lighting products is 3-4 weeks. If the product quality is not up to the standard, the date may be extended. Submit the report to Australia for review   need to provide t he SAA certif

The Role of the REACH Certification:

图片
  a . Provide high protection of human health and the environment from the use of chemicals . b .The persons (manufacturers and importers) who bring the chemicals to the market are responsible for, understand, and manage the risks associated with their use. c. allows the free trade  of matter in the EU markets. d . Strengthen the innovation and competitiveness of the EU chemical industry. e. Promote the use of alternative methods to assess the hazardous properties of substances, such as quantitative structure-activity relationships (QSAR) and reading. f. Scope and waivers. REACH is suitable for substances produced or imported into the EU in one ton or more and, generally, to all individual chemicals themselves, preparations or articles (if the substance is released under normal and reasonably foreseeable use of articles).

UL62368-1

  What is the UL62368-1? The UL 62368-1 is the latest international product safety standard, covering audio-visual, consumer electronics and information technology products, and will completely replace the current UL60950-1 and UL60065 in the next few years. Traditional product safety standard is the summary of past bad experience and induction: passively wait for the new technology to have an accident in the market before introducing solutions into regulations .   S ince   it  is based on the accident is absolutely slower than the accident, so the traditional standard development always with product innovation, even often let a person feel standard provisions limit hindered the development of science and technology products. UL62368-1 abandon the past Lock the Stable Door After the Horse haseen Stolen thinking, using Hazard-Based Safety Engineering (HBSE) mode of thinking, no matter how the technology change from the application of energy, and all kinds of energy sources can be quanti

ROHS certified product range

  The RoHS (Restriction of Hazardous Substances Directive) directive is an EU directive on restricting the use of certain hazardous substances in electronic and electrical equipment. The RoHS certified product range mainly includes: Large household appliances Small household appliances Information technology and communications equipment Consumer equipment illuminating attachment power tool Electric toys, recreational and sports equipment, etc. The six harmful substances restricted by the RoHS directive include lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr6+), polybromated biphenyls (PBs) and polybromated diphenyl ethers (PBDEs). The substance content must be below the specified limit value. www.uni-lab.hk/

The Amazon CPC Certificate Test project

  The Amazon CPC certificate is a certification document indicating that children's products sold in the US market must comply with the requirements of the US Consumer Goods Safety Improvement Act (CPSIA) and should be provided by the manufacturer or importer. The CPC certificate proves that the product has passed the necessary tests and complies with all applicable child product safety rules. The CPC certificate test items usually include: Physical and mechanical testing Flammability test chemical test Labbel and warning language tests Electrical safety test Radiation test The CPC certificate must contain details of the product, test results, applicable regulations and standards, and contact information for the manufacturer or importer. If the product does not have a CPC certificate or the certificate does not meet the requirements, Amazon may prohibit the product from being sold on its platform. www.uni-lab.hk/ hofferlau@uni-lab.hk

Three comprehensive test

  Three comprehensive test: vibration-temperature-humidity, is by a constant temperature and humidity test box or a rapid lifting temperature test box and vibration table combined of test equipment to achieve the test conditions. Three comprehensive test is enough to carry out the influence of temperature and humidity and vibration on the product. Compared with the role of a single factor, it can more truly reflect the electrical and electronic products in the process of transportation and actual use of the temperature and humidity and vibration composite environment change adaptability, expose the defects of products, is an essential and important test means for the whole process of new product development, prototype test, product qualification identification test. A pplied range: Temperature and humidity and vibration three comprehensive tests are widely used in aviation, aerospace, military, electrical, electronic and other products and parts. Three comprehensive test for product an

Amazon Mobile Power charger UL2056 test report

  UL2056 is the standard for mobile power supply, aiming to protect consumers from personal and property damage caused by mobile power supply, while helping manufacturers reduce the risk of expensive product recovery and brand damage. UL2056 Test reports generally contain the following tests: Electrical test Mechanical testing drop test Squeeze test environmental testing waterproof test Dust test For mobile power supplies sold on Amazon's e-commerce platform, UL2056 certification is usually mandatory .

Lamp reliability salt spray test

  Lamp reliability Salt spray test is an environmental test used to assess the corrosion resistance of lamps and their materials in a salty wet environment. This test usually simulates the corrosion conditions in a marine environment or an industrial polluted environment to ensure that the lamp can resist corrosion in practical use and maintain its function and appearance. During the test, the lamp sample is placed in a closed test room, where a certain concentration of saline solution is continuously sprayed to form a salt spray. Testing usually lasts for a certain period of time, depending on the test requirements and product standards.

How to use the tension test Tensile Testing machine

  Tensile Testing Machines is a kind of instrument used for measuring the geometric parameters of materials (metal, plastic, fiber, etc.) and static dynamic mechanical characteristics under tensile load. Tensile testing machines through the opening of the sample across (to determine the size and shape according to the standards or specifications), with the tensile strain stress into meaningful numerical results, in order to accurately judge and analyze the tensile properties of various materials. Now let's take a look at the steps of using the Tensile Testing machine The use steps are as follows: Preparation: fix the material sample to be tested on the test machine, and adjust the fixture and sensor of the test machine. Set test parameters: set mode, speed, range for testing. Start the test: Start the test, the test machine will apply force to the material, and record the test data. End test: After the test, stop the operation of the test machine and save or print the test data. Da

US ASTM F963

  ASTM is a mandatory certification of toy testing in the United States. Whenever the toy products are exported to the United States, they need to do ASTM testing. ASTM F963 Is a toy testing standard developed by the National Department of Standards of the United States. The latest version is ASTM F963-17 and has become a mandatory standard on September 01,2017. American Toy Safety Test ASTM F963 Standard details: 1. Supplement some references to food and cosmetics, mainly standard methods for microbiological testing, CFMethods M-1, M-2, M-3 and M-6; USP Volume 35 Methods 61, Methods 62 and Chapter 1231; and FDA's Microbiological Analysis Manual. 2. Supplement the key instructions on the inadvertent omission of ejection toys in 2016 edition, indicating that KED (kinetic energy density) is only suitable for ejection and arrow toys with kinetic energy above 0.08J. 3. Revision of some relevant test details such as low-power circuit in electric toy testing. 4. Add and make it clear tha

EN50332

EN50332 is divided into two parts, EN5032-1 and EN50332-2 .   A nd EN50332-2 is divided into EN5032-2-1 (player output voltage) and EN5032-2-2 (headset Broadband characteristic voltage test). The EN5032-1 includes the maximum sound pressure level measurement, for the performance of the player and the headset, the EN5032-2 includes two tests of the maximum output voltage and the broadband characteristic output voltage of the headset. Test requirements   of EN50332: 1. The product shall be tested in the silent room to avoid interference from environmental noise. The headphones are mounted on standard artificial ears, and the microphone is mounted to collect the sound of the headphones. Audioanalyser a nalyze and record the maximum sound pressure value (LAeq) for each audio. The standard sound source used in the test is the IEC60268-1. 2. The signal intensity of audio products playing digital signal (CD, DVD, MP3) is - 10dB, and analogue signal cassette is-6dB. The FM radio requires an an

FCC certification requires the submission list and requirements are as follows

  1) FCC Application form: the application company name, address, operator information, product name and model, use standards and other information are required to be accurate; 2) FCC Authorization letter: it shall be signed and sealed by the applicant company and scanned into electronic files; 3) FCC Confidential letter: Confidential letter is an agreement signed between the application company and the CCB organization for the confidentiality of product data, which shall be signed and sealed by the applicant of the application company and scanned into electronic files; 4) Box diagram: all crystal vibration, and crystal vibration frequency need to be drawn, and keep consistent with the circuit diagram; 5) Circuit diagram: it must be consistent with the crystal vibration frequency, number and position of the crystal vibration in the block diagram; 6) Line description: the requirement is in English, and the function realization principle of the product is described clearly; 7) Operating