How to use the tension test Tensile Testing machine

  Tensile Testing Machines is a kind of instrument used for measuring the geometric parameters of materials (metal, plastic, fiber, etc.) and static dynamic mechanical characteristics under tensile load. Tensile testing machines through the opening of the sample across (to determine the size and shape according to the standards or specifications), with the tensile strain stress into meaningful numerical results, in order to accurately judge and analyze the tensile properties of various materials. Now let's take a look at the steps of using the Tensile Testing machine The use steps are as follows: Preparation: fix the material sample to be tested on the test machine, and adjust the fixture and sensor of the test machine. Set test parameters: set mode, speed, range for testing. Start the test: Start the test, the test machine will apply force to the material, and record the test data. End test: After the test, stop the operation of the test machine and save or print the test data. Da...

Salt spray test

图片
  Salt spray test is a commonly used environmental simulation accelerated corrosion test method, which is mainly used to evaluate the corrosion resistance of metal materials and their coatings, coatings, paints and other surface treatment processes. This test accelerates the corrosion process on the material surface by simulating the corrosion conditions in the Marine environment or industrial atmosphere, in order to assess the corrosion resistance of the material in a short period of time. Main test items: salt spray test (neutral, acetic acid, copper accelerated acetic acid), cyclic corrosion test, condensate water, water mist, etc.

Classification of C-tick

  C-tick is the electromagnetic compatibility component of Australia, regulated by theAustralia Community Association, and currently only controls the interference part, with the products being enforced from 1 January 1999. C-TICK Certified Product Classification: Under the Australian EMC system, the products are divided into three categories. Suppliers must apply for the C-TICK mark before selling the second and third category products. Class I products: products with low interference radiation for devices using wireless spectrum, such as manual switches, simple relays, one-way cage inductor motor, resistance, etc. Such products can voluntarily apply for the c-tick mark during production and sale. Class II products: products with high interference radiation for wireless spectrum equipment, such as switching power supply, welding machine, dimmer, most household appliances, etc. Class III products: products with very high interference to devices using wireless spectrum, namely produ...

SRRC certification

  SRRC Certification is a mandatory certification of radio transmission equipment in China to ensure its spectrum use compliance and avoid interference. Products required for certification include: 1. Wireless communication equipment: mobile phones, routers, Bluetooth headset, etc. 2. Wireless remote control: toys, drones. 3. Wireless microphone and amplification system. 4. Radio navigation equipment. 5. Radio intercom. 6. Radio broadcasting and transmitting equipment. 7. Other radio-spectrum equipment. It shall not be sold and used in China without SRRC certification.

Shower test device

图片
Suitable for external lighting, signal devices and automotive lamp shell protection, can provide realistic analog electronic products and their components during the transportation and use of the spray test may be subjected to water and other environment, to detect the waterproof performance of various products. Common operation mode 1.Preparation: First, select a test device that can simulate the real rainfall conditions. A spraying system or spray device can be used to ensure a uniform and continuous flow of rainwater. 2.Sample preparation: Cut the material to be tested into the appropriate size, usually square or rectangular. Ensure that the edges of the sample are flat, with no obvious defects. 3.Install the samples: attach the sample to the device to ensure full level and withstand rain. 4.Adjust test parameters: adjust the operating parameters of the shower, such as flow and spray Angle. 5. Experimental: turn on the shower and start the experiment. Usually the experiment lasts fo...

Vibration test

The vibration test methods can be divided into sinusoidal vibration and random vibration: Sinusoidal vibration is often used in the laboratory test method, to simulate rotation, pulsation, shock (in ships, aircraft, vehicle, space aircraft) on the vibration and the resonance frequency analysis of product structure and little note to pick up card is given priority to, it is divided into two kinds of sweep vibration and fixed frequency vibration, the harsh degree depends on the frequency range, loss amplitude, test duration. Random vibration is assessed as the seismic resistance strength of the overall structure of the fire module product and the delivery environment in the packaging state, and its severity depends on the frequency range, GRMS, test duration and axial direction.

AS / NZS 3112

图片
  AS / NZS 3112 Test Standard: AS/NZS 3112: 2017 The standard specifies the most basic safety requirements for Australian plugs and sockets with a rated ultra-low voltage of 32A for domestic and similar purposes. test item: 1. Terminal and internal connection and pin; 2. Insulation material, no removable plug; 3. Entry mode and wire buckle of the power supply cord; 4. Hand holding parts and internal connection; 5. Rating value and size of the low-voltage plug; 6. Ground connection mode and fuse; 7. Test of logo and plug; 8. Terminal and internal connection, no arrangement mode; 9. socket connecting piece, socket structure; 10. Size and grounding connection mode; 11. Prevent contact with live body and desktop installation socket; 12. Ground socket, socket with switch; 13. Test of outlets, marks and signs, and outlets with protective doors.