Headphones EN50332–2

Headphones are the electronics we often use, but listening to concerts at a loud volume for long hours hurts your ears.

The sound pressure, output voltage and audio stability test of the portable playback device are specified by the EN50332.

The test range includes all portable audio devices with headphones or headset sockets and individual headphone products.

EN50332 test classification:

EN50332 is divided into two parts, EN5032-1 and EN50332-2. And EN50332-2 is divided into EN5032-2-1 (player output voltage) EN5032-2-2 (headset Broadband characteristic voltage test). The EN5032-1 includes the maximum sound pressure level measurement, for the performance of the player and the headset, the EN5032-2 includes two tests of the maximum output voltage and the broadband characteristic output voltage of the headset.

EN50332 test requirements:

1. The product shall be tested in the silent room (silent room) to avoid interference from environmental noise.

The headphones are mounted on standard artificial ears, and the microphone is mounted to collect the sound of the headphones.

Audioanalyser Analyze and record the maximum sound pressure value (LAeq) for each audio. The standard sound source used in the test is the IEC60268-1.

2. The signal intensity of audio products playing digital signal (CD, DVD, MP3) is 10dB, and analogue signal cassette is-6dB.

The FM radio requires an antenna to transmit a passenger carrying signal (-6dB) in order to receive it.

Adjust the sound volume to the maximum volume, a total of 5 times measured, take 5 times the average.